Solutions · Building management

Every chiller, lift and genset maintained — and the whole building in view

One place for the building engineering team: preventive maintenance, requests from the floors, live equipment monitoring, alarms and energy — for office towers, malls, hospitals, hotels and apartments.

  • PM by date or running hours
  • Requests become work orders
  • Energy per meter
  • BACnet/IP, Modbus, MQTT

Live building data

Real equipment, live readings

Measured by the equipment every few seconds, on every screen and phone — not typed into a log sheet

A glass office tower with live readings pinned on it: roof cooling towers, power demand, a floor 12 temperature alarm and indoor air quality Live · BACnet/IP
Tower A · 24 floorsOffice tower · whole-building view
A plant room with insulated chilled-water pipes and valves, with live supply and return temperatures, flow, chiller power and valve position Live · BACnet/IP · Modbus
Chiller plant room · B2Chilled-water pipes, valves and pumps
A rooftop cooling tower with live condenser water temperatures, fan speed and approach Live · Modbus
Cooling tower CT-01 · roofCondenser water loop

Photos: Unsplash. Readings are sample data.

SCADA for buildings

The whole building, live — in 2D and 3D

Drawn in the AssetGrid designers and bound to BACnet/IP, Modbus and MQTT points — no code

assetgrid · 2D screen · Chiller Plant · Tower A
AssetGrid 2D SCADA screen of a chiller plant: three cooling towers, three chillers and three chilled-water pumps with live readings, flowing pipes, chiller CH-02 in alarm, and panels for chilled water, the CH-02 alarm and plant efficiency
Chiller plant screen: towers, chillers and pumps change colour with their state, pipes show flow, CH-02 is in alarm on high condenser pressure. Sample data.
assetgrid · 3D view · Tower A
AssetGrid 3D view of an office tower: each floor coloured by its temperature with floor 12 in orange, cooling towers on the roof, the chiller plant beside it with CH-02 in amber, and live panels
3D view: floors coloured by temperature, the chiller plant and live panels. Sample data.
Every floor at a glance

Floors take the colour of their temperature, so a hot floor stands out before a tenant calls.

Alarms you can see

Equipment in alarm changes colour on the 2D screen and in 3D, with the reading right beside it.

For the engineering room wall

Saved views and a tour mode run the 3D view on a wall screen; one tap opens the 2D screen of any plant.

On the phone too

The same screens run in the Android app for technicians on their rounds.

What building engineering teams deal with every day

Tenants notice every minute of downtime — the team needs to see problems first

Equipment that cannot stop

Chillers, pumps, lifts and gensets run around the clock. When one fails, every tenant feels it within minutes.

PM in binders and spreadsheets

Filter changes, lift inspections and genset runs slip when the schedule lives on paper and in one person's head.

Complaints by phone and chat

“AC not cold on floor 12” arrives in a chat group, gets buried, and nobody can say when it was fixed.

Energy is the biggest bill

Air conditioning is usually the largest share of a building's electricity, yet few teams see it per system or per floor.

What AssetGrid does for your building

Maintenance, requests, monitoring and energy on one set of asset data

Preventive maintenance

PM that follows the calendar — and the running hours

Plan every recurring job once. AssetGrid raises the work order when it falls due and keeps the history for audits and insurance.

  • Schedules by date (monthly AHU filters, yearly lift inspection) or by running hours (genset service every 250 hours)
  • Running hours counted from the equipment's run signal — no hand-written log
  • Checklists for recurring tests: weekly fire pump run, genset load test, panel inspection
  • A QR label on every asset: scan it with the phone to see its history and open a work order

Requests & work orders

From a complaint to a closed work order, on record

Every request has an owner, a priority and a due time, and the building manager can see what is open on which floor.

  • Building staff raise a request from the web or the phone, with a photo and the location
  • The engineering team approves it and turns it into a work order with a priority and a due time
  • Technicians work from the Android app: checklist, photos, parts used and sign-off
  • Contractors and their parts and services tracked through vendors and purchase orders

Live monitoring & alarms

See the plant room before someone calls

Read the values that matter from chiller controllers, VFDs, genset controllers, power meters and sensors, and act on them.

  • Alarm limits with on-call escalation by e-mail and in the app when nobody acknowledges
  • Condition rules and anomaly detection catch slow drifts, like a chiller working harder for the same load
  • Draw the chiller plant or a floor plan in the screen designer, or show the building in 3D, bound to live values
  • Every value kept as history for trends and reports

Energy

Know where every kWh goes

Connect the power meters you already have and see consumption, cost and CO₂ for each one.

  • Consumption, cost and CO₂ per meter, from its kWh counter
  • Compare the chiller plant, AHUs, lifts, lighting and tenant floors by hour, day or month
  • Excel export for the monthly report to the building owner

Every system in the building, in one asset register

Organised by building, tower, floor and room — each asset with its QR label, history, PM plan and spare parts

  • Chillers & cooling towers
  • AHU, FCU & VAV
  • Pumps & booster sets
  • Lifts & escalators
  • Gensets & ATS
  • Transformers, LVMDP & panels
  • UPS & batteries
  • Fire pumps & sprinklers
  • Water tanks, WTP & STP
  • CCTV, access & BMS panels

Example

Chiller 2 trips at 02:10 — what happens next

Spotted, escalated, fixed and on record before the morning shift

  1. 01

    Signal

    The chiller controller's trip and condenser pressure reach AssetGrid through the collector.

  2. 02

    Alarm & escalation

    The on-call HVAC technician is alerted; if nobody acknowledges in time, it escalates to the chief engineer.

  3. 03

    Work order

    A corrective work order opens on CH-02 with its history, checklist and spare parts.

  4. 04

    On site

    The technician scans the chiller's QR code, follows the checklist and records parts and photos.

  5. 05

    Closed & learned

    Downtime and the fix are on record; the next similar fault shows what worked last time.

Works with the equipment the building already has

A small collector on the building network reads the points you choose — your BMS keeps controlling

BACnet/IP

Read analog, binary and multi-state points straight from the BMS and its controllers: chillers, AHUs, VAVs, FCUs.

Modbus TCP

Power meters, VFDs, genset and chiller controllers, and RS-485 devices through a Modbus TCP gateway.

MQTT

IoT sensors and gateways: temperature, humidity, CO₂, water leaks and tank levels.

OPC UA

Plant-room PLCs and SCADA servers that publish their data over OPC UA.

See AssetGrid with your building's equipment

Start with the asset register, PM and requests on web and Android, then connect chillers, meters and gensets when you are ready. Every building is scoped and quoted on its own.

Questions from building teams

Does AssetGrid replace our BMS?

No. Your BMS keeps controlling air conditioning and lighting. AssetGrid reads the values you choose, raises alarms and work orders, and runs maintenance, requests, spare parts and energy reporting around it.

Can it read our BACnet system?

Yes. The collector reads BACnet/IP points from the BMS and its controllers, and you choose which ones to monitor. AssetGrid reads; your BMS keeps controlling.

Can we start with maintenance only?

Yes. Many teams start with the asset register, PM schedules, checklists and requests on web and Android, and connect equipment later.

We manage several towers. Does that work?

Yes. Buildings, towers, floors and rooms are locations, so assets, requests and reports can be filtered down to a single floor.

Do technicians need a computer?

No. Technicians and building staff use the Android app: scan QR codes, follow checklists, add photos and close work orders.